1.
Phys Med Biol ; 68(23)2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-37827167

RESUMO

Objective. The performance of silicon detectors with moderate internal gain, named low-gain avalanche diodes (LGADs), was studied to investigate their capability to discriminate and count single beam particles at high fluxes, in view of future applications for beam characterization and on-line beam monitoring in proton therapy.Approach. Dedicated LGAD detectors with an active thickness of 55µm and segmented in 2 mm2strips were characterized at two Italian proton-therapy facilities, CNAO in Pavia and the Proton Therapy Center of Trento, with proton beams provided by a synchrotron and a cyclotron, respectively. Signals from single beam particles were discriminated against a threshold and counted. The number of proton pulses for fixed energies and different particle fluxes was compared with the charge collected by a compact ionization chamber, to infer the input particle rates.Main results. The counting inefficiency due to the overlap of nearby signals was less than 1% up to particle rates in one strip of 1 MHz, corresponding to a mean fluence rate on the strip of about 5 × 107p/(cm2·s). Count-loss correction algorithms based on the logic combination of signals from two neighboring strips allow to extend the maximum counting rate by one order of magnitude. The same algorithms give additional information on the fine time structure of the beam.Significance. The direct counting of the number of beam protons with segmented silicon detectors allows to overcome some limitations of gas detectors typically employed for beam characterization and beam monitoring in particle therapy, providing faster response times, higher sensitivity, and independence of the counts from the particle energy.


Assuntos
Terapia com Prótons , Radiometria , Radiometria/métodos , Prótons , Silício , Ciclotrons
2.
Radiat Prot Dosimetry ; 180(1-4): 291-295, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-29415243

RESUMO

We report on a scintillator-based online detection system for the spectral characterization of polychromatic proton bunches. Using up to nine stacked layers of radiation hard polysiloxane scintillators, coupled to and readout edge-on by a large area pixelated CMOS detector, impinging polychromatic proton bunches were characterized. The energy spectra were reconstructed using calibration data and simulated using Monte-Carlo simulations. Despite the scintillator stack showed some problems like thickness inhomogeneities and unequal layer coupling, the prototype allows to obtain a first estimate of the energy spectrum of proton beams.


Assuntos
Lasers , Sistemas On-Line , Prótons , Contagem de Cintilação/instrumentação , Calibragem , Simulação por Computador , Ciclotrons , Luz , Método de Monte Carlo , Fótons , Raios X
3.
Opt Express ; 25(16): 19083, 2017 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-29041098

RESUMO

An erratum is presented to correct a reference mistake in Table 1 in Sect. 4 of [Opt. Express25, 12765 (2017)].

4.
Opt Express ; 25(11): 12765-12778, 2017 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-28786630

RESUMO

This paper reports on characterization results of a single-photon avalanche diode (SPAD) array in standard CMOS 150nm technology. The array is composed by 25 (5 × 5) SPADs, based on p+/n-well active junction along with a retrograde deep n-well guard ring. The square-shaped SPAD has a 10µm active diameter and 15.6µm pitch size, achieving a 39.9% array fill factor. Characterization results show a good breakdown voltage uniformity (40mV max-min) within each chip and 17mV/°C temperature coefficient. The median DCR is 0.4Hz/µm2, and the afterpulsing probability is 0.85% for a dead time of 150ns at 3V excess bias voltage. The peak PDP is 31% at 450nm wavelength and a good uniformity (1.1% standard deviation) is observed for the array at 5V excess bias. The single SPADs exhibit a timing jitter of 52ps (FWHM) and 42ps (FWHM) under a 468-nm and a 831-nm laser, respectively. The crosstalk probability as a function of pixel-to-pixel distance and excess bias voltage is presented, and random telegraph signal (RTS) noise is also discussed in detail.